2012 - Medical Device Postmarketing Vigilance Reporting: Update and Expectations for Manufacturers - Webinar By GlobalCompliancePanel
Date2012-06-12
Deadline2012-06-12
VenueOnline Tra, USA - United States
Keywordsonline training,Postmarketing Vigilance Reporting,MEDDEVs,Global Harmonization Task Force,European vigilance system
Websitehttp://bit.ly/JezaLC
Topics/Call fo Papers
Overview: Major postmarketing vigilance revisions are now in force. A revised medical device guidance document on postmarketing vigilance (MEDDEV 2.12-1 rev 5) came into force on January 1, 2008. Providing more guidance than the previous version, the new document includes new reporting terminology and concepts such as "periodic summary reporting" and "trend reporting."
In addition, the terms "advisory notice," "near incident," and "recall" have been eliminated or replaced. Although MEDDEVs are not legally binding, it is likely that all European Competent Authorities will follow the new guidelines and will expect organizations involved in the management and reporting of adverse incidents to follow them as well. This session will address topics such as new definitions; the guideline's extended scope, reporting criteria/timelines, filing safety notices and field safety corrective actions, and more. The new guidelines contain some controversial aspects, including the extension of their scope and the new approach of immediate reporting unless delays can be justified. However, they also provide additional clarity and more-detailed advice in many areas. The European Database EUDAMED also is described. Periodic or trend reporting under certain conditions is now allowed, as a result of the integration of certain GHTF concepts. Although a transition period was allowed until the end of 2007, the revised guidelines will undoubtedly result in the need for manufacturers, authorized representatives, and distributors to make changes to their SOPs and other documents.
Areas Covered in the Session:
Examine the latest changes to MEDDEV and Medical Device Vigilance and impact on medical device manufacturers
Recognize the "new" terminology and concepts
Report incidents as recommended by the guidance
Examine why Global Harmonization Task Force (GHTF) is an integral component of the new postmarketing vigilance guidelines
Manage expectations for reporting and timelines
Recognize which amendments impact the European vigilance system
Interpret the new guidelines that cover incidents involving devices that carry the CE mark and devices that do not carry the CE mark
Submit periodic summary reports of incidents to Competent Authorities
Examine controversial aspects of the guidelines, including the extension of their scope and the new approach of immediate reporting unless delays can be justified
Identify the conditions under which reporting is not required and why they have been expanded and clarified with no significant changes, although one reason has been removed
Who Will Benefit: This webinar will provide valuable assistance and guidance to device companies in involved in vigilance reporting. Employees who will benefit include:
All levels of management and departmental representatives and those who desire a better understanding or a "refresh" overview
Regulatory Affairs
Clinical Affairs
Quality and Compliance
Marketing & Sales
Distributors
Engineering/Technical Services/Operations
Consultants
Price List:
Live : $245.00
Corporate live : $995.00
Recorded : $295.00
webinars-AT-globalcompliancepanel.com
http://www.globalcompliancepanel.com
Phone: 800-447-9407
Fax: 302-288-6884
In addition, the terms "advisory notice," "near incident," and "recall" have been eliminated or replaced. Although MEDDEVs are not legally binding, it is likely that all European Competent Authorities will follow the new guidelines and will expect organizations involved in the management and reporting of adverse incidents to follow them as well. This session will address topics such as new definitions; the guideline's extended scope, reporting criteria/timelines, filing safety notices and field safety corrective actions, and more. The new guidelines contain some controversial aspects, including the extension of their scope and the new approach of immediate reporting unless delays can be justified. However, they also provide additional clarity and more-detailed advice in many areas. The European Database EUDAMED also is described. Periodic or trend reporting under certain conditions is now allowed, as a result of the integration of certain GHTF concepts. Although a transition period was allowed until the end of 2007, the revised guidelines will undoubtedly result in the need for manufacturers, authorized representatives, and distributors to make changes to their SOPs and other documents.
Areas Covered in the Session:
Examine the latest changes to MEDDEV and Medical Device Vigilance and impact on medical device manufacturers
Recognize the "new" terminology and concepts
Report incidents as recommended by the guidance
Examine why Global Harmonization Task Force (GHTF) is an integral component of the new postmarketing vigilance guidelines
Manage expectations for reporting and timelines
Recognize which amendments impact the European vigilance system
Interpret the new guidelines that cover incidents involving devices that carry the CE mark and devices that do not carry the CE mark
Submit periodic summary reports of incidents to Competent Authorities
Examine controversial aspects of the guidelines, including the extension of their scope and the new approach of immediate reporting unless delays can be justified
Identify the conditions under which reporting is not required and why they have been expanded and clarified with no significant changes, although one reason has been removed
Who Will Benefit: This webinar will provide valuable assistance and guidance to device companies in involved in vigilance reporting. Employees who will benefit include:
All levels of management and departmental representatives and those who desire a better understanding or a "refresh" overview
Regulatory Affairs
Clinical Affairs
Quality and Compliance
Marketing & Sales
Distributors
Engineering/Technical Services/Operations
Consultants
Price List:
Live : $245.00
Corporate live : $995.00
Recorded : $295.00
webinars-AT-globalcompliancepanel.com
http://www.globalcompliancepanel.com
Phone: 800-447-9407
Fax: 302-288-6884
Other CFPs
- Scale-Up, Cycle Transfer, and Maximum Throughput Capability for Lyophilized Products - Webinar By GlobalCompliancePanel
- Residual Moisture Testing of Lyophilized Products - Webinar By GlobalCompliancePanel
- IT Infrastructure and Network Qualification: Step-by-Step - Webinar By GlobalCompliancePanel
- Excel Spreadsheet Validation to Eliminate 483s - Webinar By GlobalCompliancePanel
- Medical Device Supplier Quality Agreements - Webinar By GlobalCompliancePanel
Last modified: 2012-05-09 18:50:41